Baxi Boiler – Error Code E118

Baxi Error Code E118: The Baxi Boiler’s Error Code E118 means that the system water pressure is low. This can happen when there is not enough water in the boiler to properly heat your home. When the water pressure is low, the boiler may not be able to function correctly and may not provide enough heat. It is important to check the water pressure gauge on the boiler and make sure it is at the recommended level. If the pressure is too low, you may need to add more water to the system. It is also a good idea to check for any leaks in the system that may be causing the pressure to drop.

Baxi Boiler – Error Code E118

Is your Baxi boiler showing up with Error Code E118 on the screen? In this article, we’ll look at why it is happening, some potential next steps for fixing error code E118 and whether you should keep using your Baxi boiler.

What is a Baxi Error Code E118?

The Baxi Boiler’s Error Code E118 means that the system water pressure is low. This can happen when there is not enough water in the boiler to properly heat your home. When the water pressure is low, the boiler may not be able to function correctly and may not provide enough heat. It is important to check the water pressure gauge on the boiler and make sure it is at the recommended level. If the pressure is too low, you may need to add more water to the system. It is also a good idea to check for any leaks in the system that may be causing the pressure to drop.

Recommended solution/fix steps

When you see the error code E118 on your Baxi Boiler, it means that the system water pressure is low. To resolve this issue, you should first check the pressure gauge on the boiler. If the pressure is below the recommended range (usually between 1 and 1.5 bar), you will need to repressurize the system. To do this, locate the filling loop valve and slowly open it until the pressure reaches the desired level. Once the pressure is back to normal, close the filling loop valve and reset the boiler by turning it off and on again. If the error code persists or if you are unsure about the process, it is recommended to contact a qualified heating engineer for further assistance.

Related Fault Codes

Fault codes that are often associated with or mistaken for error code E118 are: E0B8, E11B, E1S8, E118, E1B6, E1Z8, E1S6, E1B8, E11S, E1B5

Can I still use my Baxi boiler?

After seeing Error Code E118 on a Baxi Boiler, which indicates that the system water pressure is low, the machine can still be operated. However, it is important to address the issue promptly to avoid any potential damage or further complications. Low system water pressure can lead to inefficient heating or even a complete shutdown of the boiler. To resolve this problem, the user should check the pressure gauge and ensure that it is within the recommended range. If the pressure is too low, the system may need to be repressurized by adding water to the system. It is advisable to consult the boiler’s manual or contact a professional technician for assistance in resolving this error code.