Coleman/Evcon Furnace – Error Code 8

Coleman/Evcon Error Code 8: The Coleman/Evcon Furnace has an error code 8 which means that the furnace has shut down due to a loss of flame. This has happened five times, causing the furnace to go into a lockout mode.

When the furnace loses its flame, it automatically shuts down to prevent any potential hazards. The error code 8 indicates that this has happened five times, which means that there may be an issue with the ignition system or the gas supply. To resolve this issue, the furnace needs to be reset by turning off the power and then turning it back on after a few minutes. If the problem persists, it is recommended to contact a professional technician to diagnose and fix the issue.

Coleman/Evcon Furnace – Error Code 8

Is your Coleman/Evcon furnace showing up with Error Code 8 on the screen? In this article, we’ll look at why it is happening, some potential next steps for fixing error code 8 and whether you should keep using your Coleman/Evcon furnace.

What is a Coleman/Evcon Error Code 8?

The Coleman/Evcon Furnace has an error code 8 which means that the furnace has shut down due to a loss of flame. This has happened five times, causing the furnace to go into a lockout mode.

When the furnace loses its flame, it automatically shuts down to prevent any potential hazards. The error code 8 indicates that this has happened five times, which means that there may be an issue with the ignition system or the gas supply. To resolve this issue, the furnace needs to be reset by turning off the power and then turning it back on after a few minutes. If the problem persists, it is recommended to contact a professional technician to diagnose and fix the issue.

Recommended solution/fix steps

When you see Error Code 8 on a Coleman/Evcon Furnace, which indicates a lockout due to loss of flame occurring five times, there are a few steps you can take to address the issue. First, check the gas supply to ensure it is turned on and the pressure is sufficient. Next, inspect the flame sensor for any dirt or corrosion and clean it if necessary. Additionally, examine the igniter and ensure it is functioning properly. If the issue persists, reset the furnace by turning off the power and then turning it back on after a few minutes. If none of these steps resolve the problem, it is recommended to contact a professional technician for further assistance.

Related Fault Codes

Fault codes that are often associated with or mistaken for error code 8 are: 0, i, Z, S, B, b, l, 3, 9, 7

Can I still use my Coleman/Evcon furnace?

After seeing Error Code 8 on a Coleman/Evcon Furnace, the machine cannot be operated until the issue causing the lockout is resolved. The error code indicates that the furnace has lost its flame five times, triggering a safety mechanism that shuts down the system to prevent further damage or danger. Attempting to operate the furnace without addressing the underlying issue could result in further lockouts or even a potential fire hazard. It is important to identify and fix the cause of the loss of flame before attempting to restart the furnace. This may require the assistance of a professional technician to ensure proper diagnosis and repair.

Category: Tag: