MUST Solar – Error Code 2

About the MUST Solar Solar Inverter Error Code 2: Maximum charging current: To configure total charging current for solar and utility chargers. (Max. charging current = utility charging current + solar charging current)

MUST Solar Solar Inverter – Error Code 2

Is your MUST Solar solar inverter showing up with Error Code 2 on the screen? In this article, we’ll look at why it is happening, some potential next steps for fixing error code 2 and whether you should keep using your MUST Solar solar inverter.

What is a MUST Solar Error Code 2?

The MUST Solar Solar Inverter has an Error Code 2, which means that: Error Code 2 on the MUST Solar Solar Inverter refers to the maximum charging current. This error occurs when the total charging current for both the solar and utility chargers needs to be configured. The maximum charging current is calculated by adding the utility charging current and the solar charging current together. To resolve this error, the user needs to adjust the settings to ensure that the total charging current does not exceed the maximum limit set by the inverter. This error code is a reminder to properly configure the charging current to prevent any potential issues or overloading of the inverter system.

Recommended solution/fix steps

To fix the error code 2 on the MUST Solar Solar Inverter, follow these steps:

1. Determine the maximum charging current required for your system. This is the sum of the utility charging current and the solar charging current.
2. Check the settings on your inverter to ensure that the total charging current is configured correctly.
3. If the settings are incorrect, access the inverter’s configuration menu or interface.
4. Adjust the utility charging current and solar charging current values to match the desired maximum charging current.
5. Save the changes and exit the configuration menu.
6. Monitor the inverter to ensure that the error code 2 is no longer displayed and that the charging current is functioning as intended.
7. If the error persists, consult the user manual or contact the manufacturer for further assistance

How to reset my MUST Solar Solar Inverter

To reset the MUST Solar Solar Inverter Error Code 2, follow these steps:

1. Identify the utility charging current and solar charging current values.
2. Calculate the total charging current by adding the utility charging current and solar charging current.
3. Access the inverter’s settings or control panel.
4. Locate the option to configure the total charging current.
5. Enter the calculated total charging current value.
6. Save the changes and exit the settings or control panel.
7. Wait for the inverter to reset and restart.
8. Check if the Error Code 2 has been resolved.

By following these steps, you can reset the MUST Solar Solar Inverter Error Code 2 related to the maximum charging current configuration

Can I still use my MUST Solar solar inverter?

The MUST Solar Solar Inverter Error Code 2 indicates that the maximum charging current needs to be configured for both solar and utility chargers. This means that the total charging current should not exceed the sum of the utility charging current and the solar charging current. While this error code may prevent the inverter from functioning properly until the charging current is properly configured, it does not necessarily mean that the appliance cannot be used. Once the charging current is properly configured, the inverter should be able to function as intended. However, it is important to address this error code promptly to ensure that the inverter is operating safely and efficiently