Rheem/Ruud Furnace – Error Code 55

Rheem/Ruud Error Code 55: The Rheem/Ruud Furnace Error Code 55 means that the pressure switch is closed when it should be open. This can happen when there is a problem with the pressure switch or the tubing that connects it to the furnace. The pressure switch is an important safety feature that ensures the furnace is operating correctly and safely. When the pressure switch is closed, it means that the furnace is not getting enough air flow, which can cause it to overheat and potentially cause a fire. If you see this error code on your Rheem/Ruud furnace, it is important to have it checked out by a professional to ensure that it is operating safely and efficiently.

Rheem/Ruud Furnace – Error Code 55

Is your Rheem/Ruud furnace showing up with Error Code 55 on the screen? In this article, we’ll look at why it is happening, some potential next steps for fixing error code 55 and whether you should keep using your Rheem/Ruud furnace.

What is a Rheem/Ruud Error Code 55?

The Rheem/Ruud Furnace Error Code 55 means that the pressure switch is closed when it should be open. This can happen when there is a problem with the pressure switch or the tubing that connects it to the furnace. The pressure switch is an important safety feature that ensures the furnace is operating correctly and safely. When the pressure switch is closed, it means that the furnace is not getting enough air flow, which can cause it to overheat and potentially cause a fire. If you see this error code on your Rheem/Ruud furnace, it is important to have it checked out by a professional to ensure that it is operating safely and efficiently.

Recommended solution/fix steps

When you see Error Code 55 on a Rheem/Ruud Furnace, which indicates that the pressure switch is closed when it should be open, follow these steps to troubleshoot and resolve the issue. First, check the pressure switch tubing for any blockages or kinks, and ensure it is properly connected. If the tubing is clear and connected correctly, inspect the pressure switch itself for any signs of damage or malfunction. Clean or replace the pressure switch if necessary. Additionally, check the venting system for any obstructions or restrictions that may be causing the pressure switch to close. Clear any blockages and ensure proper venting. If the issue persists, it is recommended to contact a professional HVAC technician for further assistance.

Related Fault Codes

Fault codes that are often associated with or mistaken for error code 55 are: 05, 5B, 5S, 5Z, 5B, 5b, 5l, 0S, 0Z, 0B

Can I still use my Rheem/Ruud furnace?

After seeing Error Code 55 on a Rheem/Ruud Furnace, the machine cannot be operated. This error indicates that the pressure switch is closed when it should be open. The pressure switch is a safety device that ensures proper airflow in the furnace. When it is closed, it means there is a blockage or malfunction in the system. Operating the machine in this state can lead to further damage or even safety hazards. It is important to address the issue causing the pressure switch to remain closed before attempting to operate the furnace again. Professional assistance may be required to diagnose and fix the problem.

Category: Tag: