Sinetech – Error Code 13

About the Sinetech Solar Inverter Error Code 13: PV insulation resistance is too low

Sinetech Solar Inverter – Error Code 13

Is your Sinetech solar inverter showing up with Error Code 13 on the screen? In this article, we’ll look at why it is happening, some potential next steps for fixing error code 13 and whether you should keep using your Sinetech solar inverter.

What is a Sinetech Error Code 13?

The Sinetech Solar Inverter has an Error Code 13, which means that: Error Code 13 on the Sinetech Solar Inverter indicates that the insulation resistance of the photovoltaic (PV) system is too low. This means that there is a problem with the insulation between the PV panels and the inverter. Insulation is important because it prevents electrical current from leaking and causing damage or safety hazards. When the insulation resistance is too low, it can lead to electrical faults or even short circuits in the system. This error code serves as a warning to the user that there is an issue with the insulation and it needs to be addressed promptly to ensure the safe and efficient operation of the solar inverter.

Recommended solution/fix steps

To fix Sinetech Solar Inverter Error Code 13, follow these steps:

1. Turn off the solar inverter and disconnect it from the power source.
2. Check the PV (photovoltaic) panels for any visible damage or loose connections.
3. Inspect the wiring between the panels and the inverter for any signs of wear or damage.
4. Clean the panels and ensure they are free from any dirt or debris.
5. Measure the insulation resistance using a multimeter. If it is below the recommended value, there may be a fault in the panels or wiring.
6. If the insulation resistance is low, contact a professional solar technician to further diagnose and repair the issue.
7. Once the problem is resolved, reconnect the inverter to the power source and turn it back on.
8. Monitor the system to ensure the error code does not reappear

How to reset my Sinetech Solar Inverter

To reset the Sinetech Solar Inverter with Error Code 13, follow these steps:

1. Turn off the inverter by switching off the main power supply.
2. Locate the DC disconnect switch, usually found near the inverter.
3. Turn off the DC disconnect switch to disconnect the solar panels from the inverter.
4. Wait for about 5 minutes to allow the inverter to fully power down.
5. After the waiting period, turn on the DC disconnect switch to reconnect the solar panels.
6. Turn on the main power supply to the inverter.
7. The inverter should now reset and the Error Code 13 should be cleared.
8. Monitor the inverter for any further issues or error codes.

Remember to always exercise caution when working with electrical appliances and consult a professional if needed

Can I still use my Sinetech solar inverter?

After seeing fault code 13 on the Sinetech Solar Inverter, indicating that the PV insulation resistance is too low, it is not recommended to continue using the appliance. This fault code suggests that there is a problem with the insulation of the photovoltaic (PV) system, which could potentially lead to electrical hazards or damage to the inverter. It is important to address this issue promptly by contacting a professional technician or the manufacturer for assistance. Continuing to use the inverter with this fault code could pose a safety risk and may result in further damage to the appliance or the PV system

Category: Tag: