Utica Boiler – Error Code 60

About the Utica Boiler Error Code 60: Thermostat polarity error.

Utica Boiler – Error Code 60

Is your Utica boiler showing up with Error Code 60 on the screen? In this article, we’ll look at why it is happening, some potential next steps for fixing error code 60 and whether you should keep using your Utica boiler.

What is a Utica Error Code 60?

The Utica Boiler has an Error Code 60, which means that: Error Code 60 on a Utica Boiler means there is a problem with the polarity of the thermostat. Polarity refers to the direction of the electrical current flowing through the wires. This error occurs when the wires connected to the thermostat are not properly aligned with the correct positive and negative terminals. It could be caused by incorrect installation or a wiring issue. When this error code appears, it means that the boiler is unable to communicate with the thermostat properly, which can affect its ability to regulate the temperature in your home. To fix this issue, you may need to check the wiring connections and ensure they are correctly aligned with the correct terminals on the thermostat.

Recommended solution/fix steps

To fix the Utica Boiler Error Code 60, which indicates a thermostat polarity error, there are a few steps you can take. First, turn off the power to the boiler. Then, check the wiring connections between the thermostat and the boiler to ensure they are properly connected and not loose. If any wires are loose, tighten them. Next, check the thermostat itself to make sure it is wired correctly and functioning properly. If the thermostat is not working, replace it with a new one. Finally, turn the power back on to the boiler and test the system to ensure the error has been resolved. If the error persists, it may be necessary to contact a professional for further assistance

How to reset my Utica Boiler

To reset the Utica Boiler with Error Code 60 (which indicates a thermostat polarity error), follow these steps:

1. Turn off the power supply to the boiler by flipping the corresponding switch or shutting off the circuit breaker.
2. Locate the thermostat connected to the boiler and remove it from the wall or disconnect it from the wiring.
3. Check the wiring connections on the thermostat and ensure they are properly connected and secure.
4. If any wires are loose or disconnected, reconnect them firmly.
5. Reinstall the thermostat onto the wall or reconnect it to the wiring.
6. Turn the power supply back on by flipping the switch or resetting the circuit breaker.
7. Wait for a few minutes to allow the boiler to reset itself.
8. Check if the error code has cleared. If it persists, contact a professional technician for further assistance

Can I still use my Utica boiler?

After seeing the fault code “Utica Boiler Error Code 60: Thermostat polarity error,” it is likely that the appliance cannot be used until the issue is resolved. The error indicates a problem with the polarity of the thermostat, which could lead to incorrect readings or improper functioning of the boiler. It is important to address this error code as using the appliance with a polarity error could potentially cause further damage or safety hazards. It is recommended to consult the manufacturer’s manual or contact a professional technician to diagnose and fix the issue before using the appliance again

Category: Tag: