Vokera Boiler – Error Code 4

Vokera Error Code 4: The Vokera Boiler Error Code 4 means that there is not enough water pressure in the boiler. This can happen when the water supply to the boiler is not strong enough or when there is a problem with the water pressure sensor. When there is insufficient water pressure, the boiler may not be able to function properly and may not be able to heat the water or provide heat to the house. It is important to address this issue as soon as possible to ensure that the boiler is working efficiently and to prevent any further damage.

Vokera Boiler – Error Code 4

Is your Vokera boiler showing up with Error Code 4 on the screen? In this article, we’ll look at why it is happening, some potential next steps for fixing error code 4 and whether you should keep using your Vokera boiler.

What is a Vokera Error Code 4?

The Vokera Boiler Error Code 4 means that there is not enough water pressure in the boiler. This can happen when the water supply to the boiler is not strong enough or when there is a problem with the water pressure sensor. When there is insufficient water pressure, the boiler may not be able to function properly and may not be able to heat the water or provide heat to the house. It is important to address this issue as soon as possible to ensure that the boiler is working efficiently and to prevent any further damage.

Recommended solution/fix steps

When you see Error Code 4 on your Vokera Boiler, which indicates insufficient water pressure, there are a few steps you can take to resolve the issue. First, check the pressure gauge on the boiler to ensure it is below 1.5 bar. If the pressure is too low, you will need to repressurize the system. Locate the filling loop, usually a flexible hose with a valve, and slowly open the valve until the pressure reaches the recommended level. Once the pressure is restored, reset the boiler by turning it off and on again. If the error persists, it is recommended to contact a qualified heating engineer or the manufacturer’s customer support for further assistance.

Related Fault Codes

Fault codes that are often associated with or mistaken for error code 4 are:

Can I still use my Vokera boiler?

After seeing Error Code 4 on the Vokera Boiler, which indicates insufficient water pressure, the machine cannot be operated. This error code suggests that there is not enough water pressure to properly function. Insufficient water pressure can lead to various issues, such as inadequate heating or hot water supply. It is crucial to address this problem before attempting to operate the machine again. To resolve this issue, one should check the water pressure gauge and ensure it is within the recommended range. If the pressure is too low, the system may need to be repressurized or there could be a leak that needs to be fixed. It is important to consult the manufacturer’s instructions or contact a professional for assistance in resolving this error code.